<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-14 00-49-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 57 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.1 kHz 63 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 64 kHz 19077 2,1230
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 4,66 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 0:49, 14.06.2025
RT
"HARD-FI - Hard to beat (Axwell Edit) "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6203, 6207, 6205, 6201
FM Scope Max at: 64 kHz MIN: 11 kHz % above 76 kHz: 2,1230 Acquired: 2025/06/14 0.48.54 Total samples: 19077 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,4 dBr MIN: 3,3 dBr AVE: 4,66 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/06/14 0.48.53) 00.34 00.36 00.38 00.40 00.42 00.44 00.46 00.48 0 2 4 6 Pm [dBr]